LM150-23BxxR2S Series 150W AC/DC Industrial Metal Enclosure Switching Power Supply
Share
Product Overview
The LM150-23BxxR2S Series is a second-generation, ultra-compact industrial standard power supply in a metal enclosure from MORNSUN, representing a comprehensive design innovation in size, performance, and reliability. It is the optimal choice for applications demanding high power density and robust performance. This series features a universal input voltage range, dual AC/DC input capability, superior cost-effectiveness, low power consumption, high efficiency, and reinforced safety isolation. The product is safe, reliable, and delivers excellent EMC performance.
Product Models: LM150-23B05R2S, LM150-23B12R2S, LM150-23B15R2S, LM150-23B24R2S, LM150-23B36R2S, LM150-23B48R2S, LM150-23B54R2S
Key Features
- High Power Density: Compact 159mm x 97mm x 40mm metal enclosure for 150W output.
- Universal Input Range: 80 - 305VAC / 100 - 430VDC (Dual-use AC/DC input on the same terminals).
- High Efficiency: Up to 93.0% typical efficiency (at 230VAC).
- Wide Operating Temperature: -40°C to +70°C (with derating up to +85°C).
- High Isolation: 3000VAC input-output isolation (for 1 minute).
- Low Standby Power Consumption: <0.75W (at 230VAC).
- Low Ripple & Noise.
- Comprehensive Protections: Short-circuit protection (Hiccup mode, self-recovery), over-current protection (110% - 150% Io, Constant current limiting, self-recovery), over-voltage protection (Clamping, self-recovery).
- High-Altitude Operation: Suitable for applications up to 5000 meters.
- Safety Compliance: Meets EN62477 Overvoltage Category III requirements.
- High Reliability & Warranty: 3-year warranty.
Applications
Industrial controls, LED display screens, security systems, telecommunications, instrumentation, and other fields requiring high-reliability power.
Safety & EMC Compliance
- Safety Standards: Certified to GB4943.1 & BS EN/EN62368-1; complies with UL/IEC62368-1, IS13252 (Part 1), BS EN/EN60335-1, BS EN/EN61558-1, EN62477-1. Safety Class I.
-
EMC Standards:
- EMI: Conducted and Radiated Disturbance meets CISPR32/EN55032 Class B.
- EMS: Complies with IEC/EN61000-4 series, including ESD (Contact ±4kV/Air ±8kV), Radiated Immunity (10V/m), EFT/Burst (±2kV for power, ±1kV for I/O), Surge (Line-Line ±2kV/Line-PE ±4kV) etc., Performance Criterion A.
Model Selection & Output Parameters
The product is available in standard and enhanced versions: LM150-23BxxR2S-Q (with conformal coating) and LM150-23BxxR2S-QG (with double-sided conformal coating). Various kits are available.
Detailed Model Specifications:
- LM150-23B05R2S: Output Power 150W, Rated Output 5V/30A, Output Voltage Adjustment Range 4.75-5.5V, Typical Efficiency 88.5% (230VAC).
- LM150-23B12R2S: Output Power 156W, Rated Output 12V/13A, Output Voltage Adjustment Range 10.8-13.2V, Typical Efficiency 91.5%.
- LM150-23B15R2S: Output Power 157.5W, Rated Output 15V/10.5A, Output Voltage Adjustment Range 13.5-16.5V, Typical Efficiency 92.0%.
- LM150-23B24R2S: Output Power 158.4W, Rated Output 24V/6.6A, Output Voltage Adjustment Range 21.6-26.4V, Typical Efficiency 93.0%.
- LM150-23B36R2S: Output Power 154.8W, Rated Output 36V/4.3A, Output Voltage Adjustment Range 32.4-39.6V, Typical Efficiency 93.0%.
- LM150-23B48R2S: Output Power 153.6W, Rated Output 48V/3.2A, Output Voltage Adjustment Range 43.2-52.8V, Typical Efficiency 93.0%.
- LM150-23B54R2S: Output Power 151.2W, Rated Output 54V/2.8A, Output Voltage Adjustment Range 48.6-59.4V, Typical Efficiency 93.0%.
Detailed Electrical Specifications
Input Characteristics:
- Input Voltage Range: 80-305VAC; 100-430VDC.
- Input Frequency: 47-63 Hz.
- Input Current (Max.): 4.0A @ 115VAC; 2.2A @ 230VAC.
- Inrush Current (Max.): Cold start: 50A (peak) @ 115VAC, 80A (peak) @ 230VAC.
- Leakage Current: <2.0mA @ 264VAC.
- Efficiency: Meets DOE Level VI and COC Tier 2 standards.
Output Characteristics:
- Output Voltage Accuracy: ±2% (over full line, load, and temperature range).
- Line Regulation: ±0.5% (for 5V model: 90-305VAC; for others: 80-305VAC).
- Load Regulation: ±1% (10%-100% load for 5V model); ±0.5% (20%-100% load for other models).
-
Output Ripple & Noise (Peak-to-Peak, 20MHz BW):
- 5V model: 100mV max.
- 12V, 15V models: 120mV max.
- 24V, 36V, 48V, 54V models: 150mV max.
- Temperature Coefficient: ±0.03%/°C.
- Minimum Load: 10% (for stable startup and operation of 5V model).
- Standby Power: <0.75W @ 230VAC.
- Hold-up Time: Typ. 20ms @ 115VAC; Typ. 60ms @ 230VAC.
General Characteristics:
- Isolation Resistance: ≥100MΩ (tested at 500VDC).
- Operating & Storage Temperature: -40°C to +85°C.
- Operating & Storage Humidity: 20% to 90% RH (non-condensing).
- Switching Frequency: Typ. 100kHz.
-
Output Power Derating:
- Temperature Derating: Required above +70°C up to +85°C.
- Input Voltage Derating: Required for input voltages below 100VAC.
Physical & Mechanical Characteristics
- Enclosure Material: Metal (AL5052, SGCC).
- Dimensions: 159.00 x 97.00 x 40.00 mm (L x W x H).
- Weight: Typ. 580g.
- Cooling Method: Natural air convection or forced air cooling (with external fan).
- Output Voltage Adjustment: Adjustable via the onboard ADJ potentiometer (clockwise to increase).
- Installation: For end-use applications, the enclosure must be reliably connected to protective earth (PE).
Important Notes
- All specifications are measured at 25°C ambient temperature, 230VAC input, and rated output load, unless otherwise stated.
- Derating is required for high-altitude applications: above 2000m, the operating temperature must be derated.
- A minimum load (e.g., 10% for 5V model) is required for stable startup and operation.
- Forced air cooling is recommended for full-load operation, especially at high ambient temperatures. Refer to the derating curves.
- The ripple and noise measurement method uses a parallel 10µF ceramic capacitor and a 47µF electrolytic capacitor at the output.
- The power supply is a component. Final system EMC, safety, and thermal performance must be validated in the end equipment.
- Customized versions (e.g., modified output voltage) are available. Please contact us for specific requirements.
- The "P" pin (case ground) must be connected to the system's protective earth (PE).
Contact Email: Vic@feisman.cn