LI15-20BxxPR2 Series 15W AC/DC DIN Rail Mount Switching Power Supply
Share
Product Overview
The LI15-20BxxPR2 Series is a cost-effective, standard DIN rail mount, energy-efficient green power solution from MORNSUN, designed to offer high stability and strong anti-interference performance for industrial control equipment, machinery, and various applications in harsh environments. This series features a compact, lightweight, and space-saving design with excellent safety, reliability, and EMC performance.
Product Models: LI15-20B05PR2, LI15-20B12PR2, LI15-20B15PR2, LI15-20B24PR2, LI15-20B48PR2
Key Features
- Wide Input Voltage Range: 85 - 264VAC (277VAC available) / 120 - 370VDC (390VDC available). Accepts both AC and DC input on the same terminals.
- High Isolation Voltage: 4000VAC isolation between input and output.
- High Efficiency & Low Standby Power: Typical efficiency up to 87.0% (230VAC). Standby power consumption is less than 0.3W (at 230VAC input).
- Wide Operating Temperature Range: -40℃ to +70℃.
- Comprehensive Protections: Short-circuit protection (Hiccup mode, sustainable short-circuit, self-recovery), over-current protection, and over-voltage protection (clamping).
- Low Output Ripple & Noise.
- Standard DIN Rail Mounting: Can be installed on TS35x7.5 or TS35x15 standard DIN rails.
- High Reliability & Safety: Meets Overvoltage Category III (per EN61558-1). Safety Class II. MTBF >300,000 hours (MIL-HDBK-217F @25℃).
- Industrial-Grade Design: Robust construction for demanding environments.
Applications
Industrial control equipment, machinery, and other industrial devices operating in harsh environments requiring stable, reliable, and compact power solutions.
Safety & EMC Compliance
Safety Standards: Certified to IS13252 (Part 1) & EN62368-1, BS EN 62368-1; complies with UL/IEC62368-1, IEC/EN61010-1, IEC/EN61558-1, IEC60335-1.
EMC Standards:
- EMI (Emissions): Conducted and Radiated Disturbance meets CISPR32/EN55032 Class B. Harmonic Current meets IEC/EN61000-3-2 Class A.
-
EMS (Immunity): Complies with IEC/EN61000-4 series, including:
- Electrostatic Discharge (ESD): Contact ±4kV / Air ±8kV (Performance Criteria A)
- Radiated RF Immunity: 10V/m (Performance Criteria A)
- Electrical Fast Transient/Burst: ±2kV (Performance Criteria A)
- Surge: Line to line ±1kV (Performance Criteria A)
- Conducted RF Immunity: 10 Vr.m.s (Performance Criteria A)
- Voltage Dips, Interruptions: Performance Criteria B
Model Selection & Output Parameters
All models are certified (EN/BIS). Note: BIS marking is printed on the product side panel only at the time of shipment.
- LI15-20B05PR2: Output Power 12W. Rated Output 5V / 2.4A. Output Voltage Adjustment Range: 4.5 - 6.5V. Typical Efficiency: 80.0% (230VAC). Max. Capacitive Load: 2000 µF.
- LI15-20B12PR2: Output Power 15W. Rated Output 12V / 1.25A. Output Voltage Adjustment Range: 10.8 - 13.8V. Typical Efficiency: 85.0% (230VAC). Max. Capacitive Load: 1500 µF.
- LI15-20B15PR2: Output Power 15W. Rated Output 15V / 1A. Output Voltage Adjustment Range: 13.5 - 18.0V. Typical Efficiency: 85.0% (230VAC). Max. Capacitive Load: 1100 µF.
- LI15-20B24PR2: Output Power 15.2W. Rated Output 24V / 0.63A. Output Voltage Adjustment Range: 21.6 - 29.0V. Typical Efficiency: 86.0% (230VAC). Max. Capacitive Load: 700 µF.
- LI15-20B48PR2: Output Power 15.4W. Rated Output 48V / 0.32A. Output Voltage Adjustment Range: 43.2 - 55.2V. Typical Efficiency: 87.0% (230VAC). Max. Capacitive Load: 300 µF.
Note on Adjustment: The actual adjustment range may exceed the selected values. Ensure the output voltage and power level remain within the published maximum limits.
Detailed Electrical Specifications
Input Characteristics:
- Input Voltage Range: AC Input: 85 - 264 VAC; DC Input: 120 - 370 VDC.
- Input Frequency: 47 - 63 Hz.
- Input Current (Max): 0.5 A @ 115VAC; 0.25 A @ 230VAC.
- Inrush Current (Max): 15 A @ 115VAC; 25 A @ 230VAC.
- Leakage Current: < 0.5 mA @ 240VAC.
- Hot-Swap: Not supported.
Output Characteristics:
- Output Voltage Accuracy: ±2% for 5V output; ±1% for other outputs (0% - 100% load).
- Line Regulation: ±0.5% (at rated load).
- Load Regulation: ±1% (230VAC input).
- Output Ripple & Noise (Peak-to-Peak, 20MHz bandwidth): Maximum 80 mV for all models.
- Temperature Coefficient: ±0.02 %/℃.
- Standby Power: < 0.3 W @ 230VAC input.
- Minimum Load: 0%.
- Start-up Time: Maximum 2 seconds.
- Hold-up Time: 30 ms @ 230VAC.
-
Protection Features:
-
Over-Voltage Protection (OVP) Clamping Levels:
- 5V output: ≤ 6.75V
- 12V output: ≤ 16.2V
- 15V output: ≤ 22.5V
- 24V output: ≤ 36.0V
- 48V output: ≤ 64.8V
- Over-Current Protection (OCP): Constant current mode when output is between 50%-100% load; self-recovery after fault removal. Operation below 50% output is not recommended.
- Short-Circuit Protection (SCP): Hiccup mode, allows sustained short-circuit, self-recovery.
-
Over-Voltage Protection (OVP) Clamping Levels:
General Characteristics:
- Isolation Resistance: Tested at 4000 VAC for 1 minute, leakage current <6mA (Input-Output).
- Operating & Storage Temperature: -40℃ to +70℃ (operating), up to +85℃ (storage).
- Storage Humidity: Up to 95% RH.
- Operating Altitude: Up to 2000 meters.
- Cooling Method: Natural convection (fanless).
-
Power Derating:
- Temperature Derating: 5.0 %/℃ from -40℃ to -30℃; 2.5 %/℃ from +50℃ to +70℃.
- Input Voltage Derating: 1.34 %/VAC for input voltage 85VAC - 100VAC.
Note on Ripple/Noise Measurement: The test method uses a twisted pair with a 12-inch length. The terminal is paralleled with a 0.1µF ceramic capacitor and a 47µF electrolytic capacitor, measured with a 20MHz bandwidth. Refer to the "Chassis and DIN Rail Application Guide" for details.
Physical & Mechanical Characteristics
- Enclosure Material: Flame-retardant, heat-resistant plastic (UL94V-0 compliant).
- Dimensions (L x W x H): 90.00 mm x 58.00 mm x 17.50 mm.
- Weight: 60 grams (typical).
- Mounting: Standard DIN Rail (TS35 type). The rail must be grounded.
-
Pin Assignment (Bottom View):
- AC (Neutral - N)
- AC (Line - L)
- -Vo (Output Negative)
- +Vo (Output Positive)
- Wiring: Accepts 24-12 AWG wire. Maximum terminal tightening torque: 0.4 N·m.
- Adjustment: Features an ADJ potentiometer for output voltage adjustment.
Important Notes
- All specifications are measured at 25℃ ambient temperature, <75% humidity, nominal input voltage, and rated output load, unless otherwise stated.
- Power derating is required for input voltages between 85-100VAC / 120-140VDC, applying voltage derating on top of the specified temperature derating curve.
- This product is suitable for use in naturally ventilated environments. For use in enclosed environments, please consult our technical support.
- Product specifications are subject to change without notice.
- End-of-life products must be stored separately according to ISO14001 and relevant environmental regulations and disposed of by qualified units.
- Product customization is available. Please contact us for specific requirements.
Contact Email for Inquiries: Vic@feisman.cn